Login1111
  • Intersurgical Inter-Guard Breathing Filter

Intersurgical Inter-Guard Breathing Filter

Intersurgical

    Features

  • Compressible volume: 42 ml
  • Connections: 22F/15M-22M/15F
  • With luer port
  • Sterile
  • Weight: 23g
  • View all item details
Select Item :
  • SMB Code : I55-17
  • MFG Code : 1344000S
  • Pack Size : Single
  • MRP : 350
147.84 (58% Off)

Quantity :

Guaranteed Delivery - in 2-3 Business Days!
Place an order Want to place an order? Call Us +91-9821631370
  • The Intersurgical Inter-Guard Breathing Filter is designed for use in breathing systems in the operating theatre and the intensive care unit for the protection of the patient, breathing system and equipment
  • The Intersurgical breathing filters provides an effective barrier against the passage of Middle East Respiratory Syndrome-Corona viruses (MERS CoV) in respiratory breathing systems
  • Technical Specifications:
    ◦ Filtration efficiency: >99.998%
    ◦ Resistance at 30L/min: 0.8 cm H2O
    ◦ Resistance at 60L/min: 2.0 cm H2O
    ◦ Compressible volume: 42 ml
    ◦ Weight: 23g
    ◦ Connections: 22F/15M-22M/15F with luer port
    ◦ Minimum tidal volume: >150ml
  • Breathing filters are used to offer outstanding validated filtration efficiency for use in anaesthesia and intensive care. These filters are designed for the protection of the patient, hospital personnel and the equipment from potential microbial contamination.
  • Breathing filters and Heat and Moisture Exchangers (HME) help facilitate the normal warming, humidifying and filtering functions of the upper respiratory tract for a patient undergoing anesthesia or in intensive care. While heat and moisture exchangers regulate the inspired air by preventing the loss of moisture and heat, bacterial viral filters prevent transmission of hazardous particulate matter and microbes from the surrounding environment into the breathing system.
  • The use of filters is recommended to reduce the risk of cross-infection during procedures involving anesthesia if the breathing system is used for more than one patient. HME filters also reduce the need for cleaning tubing and equipment, making them more convenient for healthcare personnel when compared to the use of active humidifiers. They are better-suited for short-term use (less than or equal to 96 hours) and during patient transfer.
  • It is recommended to change the filter after each patient. The filters should be changed in every 24 hours if used on a single patient for a prolonged period.

    Brochure: Intersurgical- View PDF

100% ORIGINAL PRODUCTS

Authentic Products Direct from the brand

EASY RETURNS

Simple Returns Policy

SECURE PAYMENTS

100% Payment Protection

QUICK DESPATCH

Despatched in 1-2 business days*

Customer reviews