Login1111
  • Korsoster OPA Instrument Disinfectant 0.55% w/v Ortho Pthalaldehyde

Korsoster OPA Instrument Disinfectant 0.55% w/v Ortho Pthalaldehyde

Features

Select Item :
  • SMB Code : I8-4
  • MFG Code :
  • Pack Size : Single
  • MRP : 900
756 (16% Off)

Quantity :

Stock Unavailable
  • High level disinfectant (HLD) for medical devices
  • Used in reprocessing heat sensitive medical devices
  • Provides rapid High Level Disinfection in 12 minutes at room temperature for manual processing
  • Solution is "ready-to-use"
  • requiring no activation and has minimal odour
  • Composition: Ortho-Phthaladehyde (OPA):0.55%
  • Aqueous base containing buffering agents
  • chelating agents and a corrosion inhibitor: 99.44% .
  • Compatibility of Korsosoter OPA Solution with Materials and Medical Devices:#Compatibility with a variety of materials and reprocessd devices
  • It is compatible with metal
  • plastic
  • elastomers and adhesives commonly used in the construction of reprocessable medical devices
  • Compatible materials are: Metal (Aluminum
  • Anodized aluminum
  • Brass
  • Carbon steel
  • Chrome plated brass
  • Chrome plated steel
  • Nickel plated brass
  • Nickel silver alloy
  • Copper stainless steel
  • Titanium
  • Tungsten carbide
  • Vanadium steel)
  • Plastics (Acrylic
  • Nylon
  • Polyester
  • Polypropylene
  • PVC
  • ABS
  • Polysulfone
  • Polycarbonate
  • Poluthylene
  • Polypropylene
  • Natural Rubber Latex
  • Silicone rubber)
  • Adhesives (Cyanoacrylate
  • G EPO-TEK301 Epoxy
  • EPO-TEK 353 Epoxy)
    Directions for Use:#No Activation is required
  • Record the date the container was opened on the container label
  • or in a log book
  • After opening
  • the solution remaining in the container can be used for up to 75 days (providing the 75 days does not extend past the expiration date listed on the container) until used
  • Record the date the solution was poured out of the original container into a secondary container in a log book (separate from the one mentioned above)
  • or on a label affixed to the secondary container. The solution in the secondary container cab be used for a period up to 14 days. The product must be discarded after 14 days
  • High Level Disinfection: Immerse device completely
  • filling all lumens and eliminating air pockets in KORSOSTER OPA Solution for a minimum of 12 minutes at 20? C or higher to destroy all pathogenic microoganisms. Automatic Endoscope Reprocessor to a minimum of 25?C with a minimum immersion time of 5 minutes.