B Braun Easypump II Long Term Infusion Pump

Features:
In 100 / 125/ 270 / 400 ml Latex Free Light-weight Design Designed for Ease of Use

Rs. 22,295.98 (includes GST of Rs. 2,388.85)

Get SmartCash points on this purchase

Seller: MD Labs
Notify me when this product is in stock



Description

- Advantages:

- Reduced work load for health care workers

- Safe and flexible therapy options

- Suitable for hospital and home use

- Discreet and comfortable therapy

- Easypump II is latex-free and free of DEHP in the fluid path

- How to connect Easypump II:

- Wash and disinfect hands thoroughly

- Check patient data, medication and expiration date on the label

- Make sure the pump is at room temperature

- Open the closing cone of the patient connector

- Prior to connecting to the patient, the entire pump system must be primed

- Disinfect the connection ports and consider the exposure time

- Connect the patient connector to the venous access device

- Make sure that the flow restrictor is taped on the patient’s skin

- Make sure that the filter is not covered by any material

- Open the clamp – the infusion should begin automatically

- How to disconnect Easypump II:

- Wash and disinfect hands thoroughly

- Close the clamp on the pump

- Close your venous access device

- Disconnect the pump from the venous access device

- Disinfect the connection as instructed by your healthcare provider

- Close the Easypump II

- Dispose off the pump as instructed by your healthcare provider


- The B Braun Easypump II Elastomeric Infusion Pump are designed to give clinicians and nurses the option of delivering pre-determined amounts of medication to the patient in a continuous and accurate manner, either at the hospital or at home

- Easypump is independent of main power supplies or batteries, enabling the patient to be treated in an ambulatory manner

- Its's small, light-weight design makes pump easy to transport in a discreet carry pouch

- The device is designed for increased mobility and it does not require any batteries, power cords or IV poles to function

- Benefits for Pharmacy:

- Silicone elastomer designed for easy filling

- Transparent balloon construction to help facilitate easier inspection for particulates

- Color coding for flow rate indentification

- Air elimination filter and particulate filter

- Comprehensive chemical drug stability data

- No programming or rate changing necessary

- No batteries or electronic devices required

- Benefits for Nursing:

- Color coding for flow rate identification

- Sliding Core technology designed for consistent, concentric balloon contraction

- Single-use system designed for clean and easy handling

- Unique Comfort Cap design helps protect filling port

- Easypump II is for patients who receive a treatment in an ambulatory setting and/or at home. In general, the device is not restricted to a special gender. Easypump II can be used for both adult and pediatric patients.

- Medication is delivered to the patient by positive pressure applied by the elastomeric membrane. The flow rate is determined by the combination of the flow regulation device (flow restrictor) and the positive pressure of the elastomeric membrane.

- This pressure delivers the solution against the back pressure of catheters and blood pressure in the patient. Back pressure affects the flow rate.

- Fixed flow rate design requires no programming or drop counting

- The The B Braun Easypump II is latex-free and free of DEHP in the fluid path

- The product Easypump II ST/LT is made of raw materials that both in combination and for themselves do not need to be disposed separately. If used correctly according to the Instructions For Use, no thermal or chemical influences can alter the used materials in a manner that would require separate disposal. Disposal of used devices has to be ensured by the healthcare provider to be in accordance to clinical waste management regulation in each respective country where the medical devices are used.

- Easypump Elastomeric Infusion Pump is single-use only and designed to be safely disconnected and discarded

- Indication:

- Easypump II is most commonly used in the fields of chemotherapy, antibiotics and IV pain therapy

- Precautions:

- Temperature dependency: Easypump is designed to work at room temperature 23 °C +/– 2 °C (73 °F +/– 3.6 °F). The flow restrictor is calibrated to work at 31 °C (88 °F). To maintain a stable flow rate the flow restrictor should be in close contact with the patient’s skin at all times (31 °C). For every 1 °C above or below this temperature, the flow rate will increase or decrease by approximately 3%. An increase in temperature results in an increase in flow rate and vice versa.

- If Easypump II needs to be stored in the refrigerator or freezer, allow the unit to warm up to room temperature before usage. Storage should not exceed a maximum duration of 30 days, deducting the pump specific nominal infusion time (Example: Maximum 30 days – nominal infusion time 5 days = 25 days maximum storage).

- If storage in freezer is intended, line must not be primed since the filter can be damaged.

- MRI compatible

- During epidural application the flow rate may increase

- Delivery time can increase significantly as a result of extended storage time

- Underfilling and /overfilling: Filling the pump less than nominal volume generally results in a shorter delivery time. Filling the pump more than the nominal volume results in a longer delivery time.

- Diluent dependency: Easypump flow rates are calculated on basis of using 0.9 % NaCl. Using dextrose (D5W) as diluent or the addition of any drug of a higher viscosity than normal saline will increase delivery time (e.g. by 10 % in case of dextrose [D5W], see figure 1).

- The system should not be primed when the pump is filled with Dextrose, as the flow rate could decrease significantly

- An uneven inflation of the pump during the filling process has no effect on the flow rate

- Air bubbles in the silicone sleeve would not affect the functionality of the pump. There is an air vent in the filter which is capable to filter out the entrapped air bubbles. The silicone sleeve has the properties of gas permeability, therefore the air entrapment in the silicone sleeve can be diffused out of the pump.

- Warning:

- Do not use if package has been opened or is damaged

- Single use only. Do not re-sterilize or re-use

- Re-use of single-use devices creates a potential risk for patient or user. It may lead to contamination and/or impairment of functional capability. Contamination and/ or limited functionality of the device may lead to injury, illness, or death of the patient.

- Elastomeric pumps should not be used in patients with known hypersensitivity to any of the materials of the device

- Elastomeric pumps should only be applied by healthcare workers who have been adequately trained in this technique

- There is no alarm or alert when flow interruption occurs which would advise the user of the potential for serious injury or death due to stoppage or under delivery

- The Infusion Pump is available in 4 variants:

- Filling Volume: 100 ml, Flow Rate: 2 mL/h

- Filling Volume: 270 ml, Flow Rate: 2 mL/h

- Filling Volume: 125 ml, Flow Rate: 5 mL/h

- Filling Volume: 400 ml, Flow Rate: 5 mL/h

Shipping & Delivery

Returns:

To return an item, customers must notify us through our Website or by email and a prompt response is assured to such notifications. Once the Product return/complaint request has been raised by you, AMPL shall initiate a process to vet the request and proceed accordingly.

The option to return will be allowed to you at the sole discretion of AMPL, and such requests may only be considered in the following cases:  

  1. Products were received in a damaged condition; 
  2. Products were received in packaging that had already been opened; 
  3. Due to a Product complaint after verification by AMPL; 
  4. When Product is received with remaining expiry period of less than 6 months from date of dispatch or in the event that only 50% or less of shelf life is remaining from date of receipt whichever is lesser (unless already confirmed and agreed by the customer);  
  5. Incorrect order processing, where you have placed an order for one item code but a different item code was dispatched by AMPL; 
  6. Shipment of short quantity; 
  7. When the time period since order confirmation exceeds 30 days - the order is automatically cancelled and a refund (where applicable) is initiated; 
  8. The customer is required to initiate a return request with 7 days of receipt of the product; 
    • Refunds are applicable for products received in un-opened and un-used condition.
    • If opened but returned in the original packing and working condition, customer will be eligible for credit note/ replacement of same or greater value.
  9. When an order has been confirmed and not yet been shipped, the customer can cancel the order from the order tracking mechanism.
  10. For orders > Rs. 20,000, products can only be fully exchanged, not refunded in case of any manufacturing defect or damage during transit.
  11. Rehabilitation products are not eligible for returns, refunds or replacements. In case of a manufacturing defect, damage in transit or incorrect product shipment, the product will be eligible for replacement only.

In any of the above cases, after due verification from AMPL's end if required:

  1. If payment has been made by credit card / debit card through the designated payment gateway, then the refund amount will be reversed back to your credit card / bank account within 15 days of receipt of the returned goods. Sometimes financial organizations take a longer time to process the refund request. 
  2. If payment has been made by a NEFT / RTGS transfer has been made then the refund amount will be reversed back to your bank account within 15 days of receipt of the returned goods; 
  3. If payment has been made by Cash on Delivery method then the refund amount will be transferred to your bank account (as per bank account details provided by you) within 15 days of receipt of the returned goods;

Shipping:

AMPL endeavours but does not guarantee to deliver the products to customers within 10 business days from the date of placing your order depending upon the shipping location. Factors such as delay in delivery through the courier partner, transporters' strike etc. may also affect delivery timelines. AMPL will not be liable for any loss or expenses sustained by the Buyer arising from any delay in the delivery of the Products howsoever caused.
  • AMPL reserves the right to make delivery of the products order in partial shipments. If the Products are to be delivered in instalments, each delivery will constitute a separate contract. You may not treat the contract (as a whole) as repudiated if AMPL fails to deliver any one or more of the instalments or if you have a claim in respect of any one or more of the instalments.
  • If a customer fails to take delivery of the Products, AMPL may at its discretion charge you for the additional shipping cost.
  •