Login1111
  • Niscomed CMS 7000 Plus Multi Parameter Patient Monitor

Niscomed CMS 7000 Plus Multi Parameter Patient Monitor

Features

Select Item :
  • SMB Code : I80-9
  • MFG Code : CMS 7000 Plus
  • Pack Size : Single
  • MRP : 47880
47456.64 (1% Off)

Quantity :

  • The Niscomed CMS 7000 Plus Multi Parameter Patient Monitor has a 12.1 inch colour TFT LCD display with waveforms upto 8 Channels
  • It is portable supported by a streamline handle design
  • The monitor is suitable for Adult to Neonate patients
  • The machine allows to measure one channel ECG anytime, anywhere you like
  • It displays ECG waveform, heart rate, analysis results and battery status on the backlit LCD
  • The measurement results transmission to PC by USB mode
  • The device is equipped with an auto power-off while no key is pressed in 30 seconds
  • The auto-evaluation is based on detected heart data
  • 2 batteries can take at least 500 times measurement
  • Technical Specifications for ECG:
    - 5-lead or 12-lead selectable
    - Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
    - Lead selection: I; II; III; avR; avL; avF; Vx; CAL
    - Gain selection: ×0.25,×0.5,×1,×2,auto
    - Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
    - Accuracy: ±1bpm or ±1%, whichever is greater
    - Protection: Withstand 4000V AC/50Hz voltage in isolation against electrosurgical and defibrillation
    - Calibration signal: 1mV±5%
    - Operation modes: Diagnostic, Monitor, Surgery
    - Heart rate range: Adult: 15-300bpm Paediatric/ Neonatal: 15-350bpm
    - Measurement range: -2.0mV~2.0mV
    - S-T detection: YES, Arrhythmia analysis: YES
    - Alarm: YES, audible and visual alarm, alarm events recallable
  • Technical Specifications for NIBP:
    -Method: Oscillometry
    - Operation modes: Manual/Automatic/STAT
    - Measurement unit: mmHg/KPa selectable
    - Gain selection: ×0.25,×0.5,×1,×2,auto
    - Measurement types: Systolic, Diastolic, Mean
    - Measurement range: Adult: 10-270mmHg
    - Over-pressure protection: YES
    - Resolution: 1mmHg
    - Accuracy: The mean error shall be less than ±5 mmHg ,the standard deviation shall be less than ±8mmHg
    - Alarm: Systolic,Diastolic,Mean
  • Technical Specifications for SPO2:
    - Measurement range: 0-100%
    - Accuracy: ±2%(70~100%);0~69% unspecified
    - Alarm range: 0-100%
  • Technical Specifications for Respiration:
    - Method: RA-LL impedance
    - Measurement range:Adult: 0-120rpm, paediatric/neonatal:0-150rpm
    - Apnea alarm: YES
  • Technical Specifications for IBP:
    - Channel: 2 channels
    - Pressure transducer:Sensitivity: 5( mV/V/mmHg)
    - Transducer sites: ART, PA, CVP, RAP, LAP, ICP
    - Alarm range: -10~300mmHg